A smart relay with an adjustable on or off function. The delay can be adjusted from 0.1 second to 1 hour. The relay has one input and an output that is normally connected (NC) and another output that is normally open (NO).
The relay can only be set as either a delay on or delay off, but you can set two in series, so the first has a delay on and the last has a delay off.
The relay is max 10A and 250V for AC, 10A and 30V for DC.
Setup with jumpers
There is a lot of jumpers that can be adjusted for setting up the controllers.
If there is a jumper on S6, the controller will be delayed off. The controller will then always activate the relay when activated and after the set delay - deactivated.
If this jumper is placed on S7 instead, there is a delayed on. The relay will be off when the controller is powered and then it will be on after the delay is activated.
S5 is typically not activated, as it is only needed if you run AC through the relay.
Setting up the delay
S1 = 0 and S2 = 1 and S4 = 0 |
0,13 to 1,3 seconds |
S1 = 0 and S2 = 1 and S4 = 1 |
1,5 to 14,5 seconds |
S1 = 1 and S2 = 0 and S4 = 0 |
0,5 to 5,25 seconds |
S1 = 1 and S2 = 0 and S4 = 1 |
6 to 58 seconds |
S1 = 0 and S2 = 0 and S4 = 0 |
4,4 to 42 seconds |
S1 = 0 and S2 = 0 and S4 = 1 |
48 to 463 seconds |
S1 = 1 and S2 = 1 and S4 = 0 |
38 to 340 seconds |
S1 = 1 and S2 = 1 and S4 = 1 |
389 to 3700 seconds |
Facts for Without enclosure
A smart relay with an adjustable on or off function. The delay can be adjusted from 0.1 second to 1 hour.
Vis fuld beskrivelse